The paper describes the performance of a new pulse sequence design and estimation approach for increasing the maximum detectable velocity in synthetic aperture (SA) velocity imaging. Measurements are conducted for conventional imaging for comparing the velocity range detectable by a directional Transverse Oscillation (TO) autocorrelation estimator to a new cross-correlation estimator. For conventional focused emissions a 192-elements, 3 MHz convex array transducer is used together with the SARUS experimental scanner on a flow rig at beam-toflow angles of 60◦, 70◦ and 90◦. Here the new estimator always yields a higher precision, and the aliasing limit is increased by a factor 3. The new SA inter-spaced scheme was investigated using Field II simulations and SARUS measurements. A 3 MHz, 128-elements phased array was employed with a 5 virtual source emissions scheme for flow estimation and 15 emissions for B-mode imaging. The scheme was interleaved three times for a positive, negative, and positive transmission, so that nonlinear pulse inversion also could be made. The experiments were conducted at three angles and for 4 different pulse repetition frequencies. A peak transverse velocity of 0.51 m/s could be estimated at fprf=450 Hz, translating to 5.6 m/s at fprf=5 kHz showing the theoretical increase of a factor 10 predicted in the accompanying theory paper.
Original languageEnglish
JournalI E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control
Volume66
Issue number6
Pages (from-to)1032-1038
ISSN0885-3010
DOIs
Publication statusPublished - 2019

Keywords

  • Synthetic aperture
  • Ultrasound imaging
  • Velocity estimation

Cite this

@article{5ce07525a6704faf99d3c1acebebe6d5,
title = "Estimation of High Velocities in Synthetic Aperture Imaging: II: Experimental Investigation",
abstract = "The paper describes the performance of a new pulse sequence design and estimation approach for increasing the maximum detectable velocity in synthetic aperture (SA) velocity imaging. Measurements are conducted for conventional imaging for comparing the velocity range detectable by a directional Transverse Oscillation (TO) autocorrelation estimator to a new cross-correlation estimator. For conventional focused emissions a 192-elements, 3 MHz convex array transducer is used together with the SARUS experimental scanner on a flow rig at beam-toflow angles of 60◦, 70◦ and 90◦. Here the new estimator always yields a higher precision, and the aliasing limit is increased by a factor 3. The new SA inter-spaced scheme was investigated using Field II simulations and SARUS measurements. A 3 MHz, 128-elements phased array was employed with a 5 virtual source emissions scheme for flow estimation and 15 emissions for B-mode imaging. The scheme was interleaved three times for a positive, negative, and positive transmission, so that nonlinear pulse inversion also could be made. The experiments were conducted at three angles and for 4 different pulse repetition frequencies. A peak transverse velocity of 0.51 m/s could be estimated at fprf=450 Hz, translating to 5.6 m/s at fprf=5 kHz showing the theoretical increase of a factor 10 predicted in the accompanying theory paper.",
keywords = "Synthetic aperture, Ultrasound imaging, Velocity estimation",
author = "Jensen, {J{\o}rgen Arendt}",
year = "2019",
doi = "10.1109/TUFFC.2019.2906390",
language = "English",
volume = "66",
pages = "1032--1038",
journal = "I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers",
number = "6",

}

Estimation of High Velocities in Synthetic Aperture Imaging: II: Experimental Investigation. / Jensen, Jørgen Arendt.

In: I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control, Vol. 66, No. 6, 2019, p. 1032-1038 .

Research output: Contribution to journalJournal articleResearchpeer-review

TY - JOUR

T1 - Estimation of High Velocities in Synthetic Aperture Imaging: II: Experimental Investigation

AU - Jensen, Jørgen Arendt

PY - 2019

Y1 - 2019

N2 - The paper describes the performance of a new pulse sequence design and estimation approach for increasing the maximum detectable velocity in synthetic aperture (SA) velocity imaging. Measurements are conducted for conventional imaging for comparing the velocity range detectable by a directional Transverse Oscillation (TO) autocorrelation estimator to a new cross-correlation estimator. For conventional focused emissions a 192-elements, 3 MHz convex array transducer is used together with the SARUS experimental scanner on a flow rig at beam-toflow angles of 60◦, 70◦ and 90◦. Here the new estimator always yields a higher precision, and the aliasing limit is increased by a factor 3. The new SA inter-spaced scheme was investigated using Field II simulations and SARUS measurements. A 3 MHz, 128-elements phased array was employed with a 5 virtual source emissions scheme for flow estimation and 15 emissions for B-mode imaging. The scheme was interleaved three times for a positive, negative, and positive transmission, so that nonlinear pulse inversion also could be made. The experiments were conducted at three angles and for 4 different pulse repetition frequencies. A peak transverse velocity of 0.51 m/s could be estimated at fprf=450 Hz, translating to 5.6 m/s at fprf=5 kHz showing the theoretical increase of a factor 10 predicted in the accompanying theory paper.

AB - The paper describes the performance of a new pulse sequence design and estimation approach for increasing the maximum detectable velocity in synthetic aperture (SA) velocity imaging. Measurements are conducted for conventional imaging for comparing the velocity range detectable by a directional Transverse Oscillation (TO) autocorrelation estimator to a new cross-correlation estimator. For conventional focused emissions a 192-elements, 3 MHz convex array transducer is used together with the SARUS experimental scanner on a flow rig at beam-toflow angles of 60◦, 70◦ and 90◦. Here the new estimator always yields a higher precision, and the aliasing limit is increased by a factor 3. The new SA inter-spaced scheme was investigated using Field II simulations and SARUS measurements. A 3 MHz, 128-elements phased array was employed with a 5 virtual source emissions scheme for flow estimation and 15 emissions for B-mode imaging. The scheme was interleaved three times for a positive, negative, and positive transmission, so that nonlinear pulse inversion also could be made. The experiments were conducted at three angles and for 4 different pulse repetition frequencies. A peak transverse velocity of 0.51 m/s could be estimated at fprf=450 Hz, translating to 5.6 m/s at fprf=5 kHz showing the theoretical increase of a factor 10 predicted in the accompanying theory paper.

KW - Synthetic aperture

KW - Ultrasound imaging

KW - Velocity estimation

U2 - 10.1109/TUFFC.2019.2906390

DO - 10.1109/TUFFC.2019.2906390

M3 - Journal article

VL - 66

SP - 1032

EP - 1038

JO - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control

JF - I E E E Transactions on Ultrasonics, Ferroelectrics and Frequency Control

SN - 0885-3010

IS - 6

ER -