Skip to main navigation Skip to search Skip to main content

Elimination of Carryover Contamination in Real-Time Reverse Transcriptase Loop-Mediated Isothermal Amplification for Rapid Detection of the SARS-CoV-2 Virus in Point-of-Care Testing

  • Than Linh Quyen
  • , Aaydha Chidambara Vinayaka
  • , Mohsen Golabi
  • , Huynh Van Ngoc
  • , Dang Duong Bang
  • , Anders Wolff*
  • *Corresponding author for this work

Research output: Contribution to journal › Journal article › Research › peer-review

164 Downloads (Orbit)

Abstract

Loop-mediated isothermal amplification (LAMP) is being used as a robust rapid diagnostic tool to prevent the transmission of infectious diseases. However, carryover contamination of LAMP-amplified products originating from previous tests has been a problem in LAMP-based bio-analytical assays. In this study, we developed a Cod-uracil-DNA-glycosylase real-time reverse transcriptase LAMP assay (Cod-UNG-rRT-LAMP) for the elimination of carryover contamination and the rapid detection of SARS-CoV-2 in point-of-care (POC) testing. Using the Cod-UNG-rRT-LAMP assay, the SARS-CoV-2 virus could be detected as low as 2 copies/µl (8 copies/reaction) within 45 min of amplification and 2.63 ± 0.17 pg (equivalent to 2.296 × 109 copies) of contaminants per reaction could be eliminated. Analysis of clinical SARS-CoV-2 samples using the Cod-UNG-rRT-LAMP assay showed an excellent agreement with a relative accuracy of 98.2%, sensitivity of 97.1%, and specificity of 95.2% in comparison to rRT-PCR. The results obtained in this study clearly demonstrate the feasibility of the use of the Cod-UNG-rRT-LAMP assay for applications toward the POC diagnosis of SARS-CoV-2 and on-site testing of other pathogens.
Original languageEnglish
Article number856553
JournalFrontiers in Cellular and Infection Microbiology
Volume12
Number of pages10
ISSN2235-2988
DOIs
Publication statusPublished - 2022

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Carryover contamination
  • Loop-mediated isothermal amplification (LAMP)
  • SARS-CoV-2
  • COVID-19
  • Cod uracil DNA glycosylase (Cod-UNG)
  • On-site testing
  • Point-of-care

Fingerprint

Dive into the research topics of 'Elimination of Carryover Contamination in Real-Time Reverse Transcriptase Loop-Mediated Isothermal Amplification for Rapid Detection of the SARS-CoV-2 Virus in Point-of-Care Testing'. Together they form a unique fingerprint.

Cite this