Effects of Free-Hanging Horizontal Sound Absorbers on the Cooling Performance of Thermally Activated Building Systems

Luis Marcos Domínguez Lacarte, Nils Rage, Ongun Berk Kazanci, Bjarne W. Olesen

    Research output: Contribution to journalConference articleResearchpeer-review

    366 Downloads (Pure)

    Abstract

    Thermally Activated Building Systems (TABS) have proven to be an energy-efficient solution to provide buildings with an optimal indoor thermal environment. This solution uses the structure of the building to store heat, reduce the peak loads, and decrease the primary energy demand. TABS require the heated or cooled surfaces to be as exposed as possible to the indoor space, but exposing the bare concrete surfaces has a diminishing effect on the acoustic qualities of the spaces in a building. Acoustic solutions capable of providing optimal acoustic comfort and allowing the heat exchange between the TABS and the room are desirable. In this study, the effects of free-hanging units on the cooling performance of TABS and the occupants’ thermal comfort was measured in a full-scale TABS laboratory. Investigations demonstrate that the use of freehanging sound absorbers are compatible with the performance of TABS and the occupant’s thermal comfort, but an appropriate acoustic design is needed to find the most suitable solution for each case. The results show a reduction of 11% of the cooling performance of the TABS when 43% of the ceiling area is covered with free-hanging horizontal sound absorbers, of 23% for 60% ceiling coverage ratio and of 36% for 80% coverage. Measurements in actual buildings showed an increase of the room operative temperature of 0.3 K when 50% of the ceiling surface is covered with horizontal panels and of 0.8 to 1 K for a 70% coverage ratio. According to numerical simulations using a new TRNSYS Type, the use of comfort ventilation has a considerable influence on the thermal conditions in the room; if the ventilation is removed, then the operative temperature increases by 1.8 K for a 60%-covered ceiling.
    Original languageEnglish
    JournalInternational Journal of Civil, Environmental, Structural, Construction and Architectural Engineering
    Volume11
    Issue number2
    Pages (from-to)59-63
    Publication statusPublished - 2017
    Event19th International Conference on People, Ecosystems and Built Environment - Barcelona, Spain
    Duration: 26 Feb 201727 Feb 2017
    Conference number: 19

    Conference

    Conference19th International Conference on People, Ecosystems and Built Environment
    Number19
    Country/TerritorySpain
    CityBarcelona
    Period26/02/201727/02/2017

    Keywords

    • Acoustic comfort
    • Concrete core activation
    • Full-scale measurements
    • Thermally activated building systems
    • TRNSYS