Abstract
Electronic enclosure design and the internal arrangement of PCBs and components influence microclimate inside the enclosure. This work features a general electronic unit with parallel PCBs. One of the PCB is considered to have heat generating components on it. The humidity and temperature profiles near the surface of PCBs depend on various factors like inter-PCB spacing, controlled opening size, and heat capacity of various parts. The effect of above mentioned factors on the humidity and temperature profiles are investigated for both transient and steady state operating conditions of the electronic device. The experiments are conducted for the case of condensed water present in the enclosure. A rectangular enclosure made of aluminium is used for the study. PCBs closer to heated surfaces are found to have lower relative humidity and less probability to failure. This is confirmed by impedance measurements on the PCBs. Enclosures with smaller opening sizes are observed to have lower relative humidity. Results also show possibility of using heat capacity of materials to store and release heat energy for control of humidity. This paper provides an improved understanding of the effect of internal geometry of the device and related enclosure design parameters on the humidity and temperature profiles inside the electronic device enclosure.
Original language | English |
---|---|
Title of host publication | Proceedings of the 16th IEEE Intersociety Conference onThermal and Thermomechanical Phenomena in Electronic Systems (ITherm 2017) |
Publisher | IEEE |
Publication date | 2017 |
Pages | 779-783 |
ISBN (Electronic) | 978-1-5090-2994-5 |
DOIs | |
Publication status | Published - 2017 |
Event | 2017 16th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems - Orlando, United States Duration: 30 May 2017 → 2 Jun 2017 Conference number: 16 https://ieeexplore.ieee.org/xpl/conhome/7983314/proceeding |
Conference
Conference | 2017 16th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems |
---|---|
Number | 16 |
Country/Territory | United States |
City | Orlando |
Period | 30/05/2017 → 02/06/2017 |
Internet address |
Keywords
- Humidity
- Temperature
- Thermal mass
- Electronic enclosure