Abstract

Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.
Original languageEnglish
JournalIEEE Access
Volume7
Issue number1
Pages (from-to)6297-6309
ISSN2169-3536
DOIs
Publication statusPublished - 2019

Keywords

  • Axial localization
  • Centre of mass
  • Multiple focusing
  • Normalized sharpness
  • Super-resolution ultrasound

Cite this

Diamantis, Konstantinos ; Anderson, Tom ; Jensen, Jørgen Arendt ; Dalgarno, Paul A. ; Sboros, Vassilis. / Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging. In: IEEE Access. 2019 ; Vol. 7, No. 1. pp. 6297-6309.
@article{0c215eff857340efb0b5af34ac3e3c5f,
title = "Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging",
abstract = "Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.",
keywords = "Axial localization, Centre of mass, Multiple focusing, Normalized sharpness, Super-resolution ultrasound",
author = "Konstantinos Diamantis and Tom Anderson and Jensen, {J{\o}rgen Arendt} and Dalgarno, {Paul A.} and Vassilis Sboros",
year = "2019",
doi = "10.1109/ACCESS.2018.2889425",
language = "English",
volume = "7",
pages = "6297--6309",
journal = "IEEE Access",
issn = "2169-3536",
publisher = "IEEE",
number = "1",

}

Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging. / Diamantis, Konstantinos; Anderson, Tom; Jensen, Jørgen Arendt; Dalgarno, Paul A.; Sboros, Vassilis.

In: IEEE Access, Vol. 7, No. 1, 2019, p. 6297-6309.

Research output: Contribution to journalJournal articleResearchpeer-review

TY - JOUR

T1 - Development of Super-resolution Sharpness-based Axial Localization for Ultrasound Imaging

AU - Diamantis, Konstantinos

AU - Anderson, Tom

AU - Jensen, Jørgen Arendt

AU - Dalgarno, Paul A.

AU - Sboros, Vassilis

PY - 2019

Y1 - 2019

N2 - Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.

AB - Super-resolution ultrasound mostly uses imagebased methods for the localization of single scatterers. These methods are largely based on the centre of mass (COM) calculation. Sharpness-based localization is an alternative to COM for scatterer localization in the axial direction. Simulated ultrasound point scatterer data (centre frequency f0 = 7 MHz, wavelength λ = 220 μm) showed that the normalized sharpness method can provide scatterer axial localization with an accuracy down to 2 μm (< 0.01λ), which is a two-order of magnitude improvement compared to that achievable by conventional imaging (≈λ), and a 5-fold improvement compared to the COM estimate (≈10 μm or 0.05λ). Similar results were obtained experimentally using wire-target data acquired by the Synthetic Aperture Real-time Ultrasound System (SARUS). The performance of the proposed method was also found to be consistent across different types of ultrasound transmission. The localization precision deteriorates in the presence of noise, but even in very low signal-to-noise-ratio (SNR = 0 dB) the uncertainty was not higher than 6 μm, which outperforms the COM estimate. The method can be implemented in image data as well as using the raw signals. It is proposed that signal derived localization should replace the image-based equivalent, as it provides at least a 10 times improved accuracy.

KW - Axial localization

KW - Centre of mass

KW - Multiple focusing

KW - Normalized sharpness

KW - Super-resolution ultrasound

U2 - 10.1109/ACCESS.2018.2889425

DO - 10.1109/ACCESS.2018.2889425

M3 - Journal article

VL - 7

SP - 6297

EP - 6309

JO - IEEE Access

JF - IEEE Access

SN - 2169-3536

IS - 1

ER -