Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator

Asger Bech Abrahamsen, Niklas Magnusson, Dong Liu, Ewoud Stehouwer, Ben Hendriks, Henk Polinder

Research output: Contribution to conferencePosterResearchpeer-review

216 Downloads (Pure)

Abstract

A design study of a 10 MW direct drive wind turbine generator based on MgB2 superconducting wires is presented and the cost of the active materials of the generator is estimated to be between 226 €/kW and 84 €/kw, which is lower than the threshold values of 300 €/kW of the INNWIND.EU project. A nacelle structure with a front-mounted generator is presented for further investigation of the integration of such a superconducting generator into offshore turbines with power ratings considerably larger than 10 MW.
Original languageEnglish
Publication date2014
Number of pages1
Publication statusPublished - 2014
EventEuropean Wind Energy Conference & Exhibition 2014 - Fira de Barcelona Gran Via, Barcelona, Spain
Duration: 10 Mar 201413 Mar 2014
http://www.ewea.org/annual2014/

Conference

ConferenceEuropean Wind Energy Conference & Exhibition 2014
LocationFira de Barcelona Gran Via
CountrySpain
CityBarcelona
Period10/03/201413/03/2014
Internet address

Keywords

  • Superconducting generator
  • Direct drive generator
  • Offshore wind turbine
  • Nacelle integration

Cite this

Abrahamsen, A. B., Magnusson, N., Liu, D., Stehouwer, E., Hendriks, B., & Polinder, H. (2014). Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator. Poster session presented at European Wind Energy Conference & Exhibition 2014, Barcelona, Spain.
Abrahamsen, Asger Bech ; Magnusson, Niklas ; Liu, Dong ; Stehouwer, Ewoud ; Hendriks, Ben ; Polinder, Henk. / Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator. Poster session presented at European Wind Energy Conference & Exhibition 2014, Barcelona, Spain.1 p.
@conference{05204f698391415eba0ab5c4c0d3a51e,
title = "Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator",
abstract = "A design study of a 10 MW direct drive wind turbine generator based on MgB2 superconducting wires is presented and the cost of the active materials of the generator is estimated to be between 226 €/kW and 84 €/kw, which is lower than the threshold values of 300 €/kW of the INNWIND.EU project. A nacelle structure with a front-mounted generator is presented for further investigation of the integration of such a superconducting generator into offshore turbines with power ratings considerably larger than 10 MW.",
keywords = "Superconducting generator, Direct drive generator, Offshore wind turbine, Nacelle integration",
author = "Abrahamsen, {Asger Bech} and Niklas Magnusson and Dong Liu and Ewoud Stehouwer and Ben Hendriks and Henk Polinder",
year = "2014",
language = "English",
note = "European Wind Energy Conference & Exhibition 2014, EWEA ; Conference date: 10-03-2014 Through 13-03-2014",
url = "http://www.ewea.org/annual2014/",

}

Abrahamsen, AB, Magnusson, N, Liu, D, Stehouwer, E, Hendriks, B & Polinder, H 2014, 'Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator', European Wind Energy Conference & Exhibition 2014, Barcelona, Spain, 10/03/2014 - 13/03/2014.

Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator. / Abrahamsen, Asger Bech; Magnusson, Niklas; Liu, Dong; Stehouwer, Ewoud ; Hendriks, Ben; Polinder, Henk.

2014. Poster session presented at European Wind Energy Conference & Exhibition 2014, Barcelona, Spain.

Research output: Contribution to conferencePosterResearchpeer-review

TY - CONF

T1 - Design study of a 10 MW MgB2 superconductor direct drive wind turbine generator

AU - Abrahamsen, Asger Bech

AU - Magnusson, Niklas

AU - Liu, Dong

AU - Stehouwer, Ewoud

AU - Hendriks, Ben

AU - Polinder, Henk

PY - 2014

Y1 - 2014

N2 - A design study of a 10 MW direct drive wind turbine generator based on MgB2 superconducting wires is presented and the cost of the active materials of the generator is estimated to be between 226 €/kW and 84 €/kw, which is lower than the threshold values of 300 €/kW of the INNWIND.EU project. A nacelle structure with a front-mounted generator is presented for further investigation of the integration of such a superconducting generator into offshore turbines with power ratings considerably larger than 10 MW.

AB - A design study of a 10 MW direct drive wind turbine generator based on MgB2 superconducting wires is presented and the cost of the active materials of the generator is estimated to be between 226 €/kW and 84 €/kw, which is lower than the threshold values of 300 €/kW of the INNWIND.EU project. A nacelle structure with a front-mounted generator is presented for further investigation of the integration of such a superconducting generator into offshore turbines with power ratings considerably larger than 10 MW.

KW - Superconducting generator

KW - Direct drive generator

KW - Offshore wind turbine

KW - Nacelle integration

M3 - Poster

ER -