Design and experimental tests of a rotary active magnetic regenerator prototype

Research output: Contribution to journalJournal articleResearchpeer-review

Abstract

A rotary active magnetic regenerator (AMR) prototype with efficiency and compact design as focus points has been designed and built. The main objective is to demonstrate improved efficiency for rotary devices by reducing heat leaks from the environment and parasitic mechanical work losses while optimizing the utilization of the magnetized volume. Heat transfer calculations combined with 1D AMR modeling have revealed the necessity for an insulating air gap between magnet and regenerator when designing for high efficiency. 2D finite difference AMR modeling capturing the interplay between heat transfer fluid flow and an inhomogenous time-varying magnetic field in the individual regenerator beds has been used in the design process. For one operating point a COP of 3.1 at a temperature span of 10.2 K and a cooling power of 103Wwere measured. Major issues limiting the performance have been identified and improvements are outlined for future work. © 2015 Elsevier Ltd and IIR. All rights reserved.
Original languageEnglish
JournalInternational Journal of Refrigeration
Volume58
Pages (from-to)14-21
ISSN0140-7007
DOIs
Publication statusPublished - 2015

Keywords

  • Magnetic refrigeration
  • Design
  • Model
  • Efficiency
  • Experimental

Fingerprint

Dive into the research topics of 'Design and experimental tests of a rotary active magnetic regenerator prototype'. Together they form a unique fingerprint.

Cite this