Skip to main navigation Skip to search Skip to main content

Contactless electrical measurements of transport AC losses in a 3 m long superconducting cable

  • Ole Tønnesen
  • , M. Daumling
  • , F. Gömöry
  • , E. Veje
  • , C. Traholt

    Research output: Contribution to journal › Journal article › Research › peer-review

    Abstract

    The ac transport losses at 77 K of a 3 m long high-temperature superconducting (HTS) cable conductor were measured electrically using the conventional voltage signals recorded by two pairs of voltage taps (four probe measurements). Further, the signals from two contactless pick-up loops were employed. The contactless loops were placed on the same path as the wiring of the conventional voltage taps outside the cable, whereas the return path went through the centre of the former conductor, thereby encircling all of the superconducting layers. By this arrangement the magnetic part of the ac transport losses of the HTS cable could be singled out. The measurements confirmed that at currents, I, far below the critical current, Ic, of the cable (I ≪ Ic) the losses are dominated by magnetic losses and above Ic the magnetic losses level off and resistive losses become dominating.
    Original languageEnglish
    JournalSuperconductors Science and Technology
    Volume15
    Issue number6
    Pages (from-to)898-901
    ISSN0953-2048
    DOIs
    Publication statusPublished - 2002

    Fingerprint

    Dive into the research topics of 'Contactless electrical measurements of transport AC losses in a 3 m long superconducting cable'. Together they form a unique fingerprint.

    Cite this