Consistent frequency-matching calibration procedure for electromechanical shunt absorbers

Jan Høgsberg*

*Corresponding author for this work

    Research output: Contribution to journalJournal articleResearchpeer-review

    127 Downloads (Pure)

    Abstract

    Electromagnetic and piezoelectric shunt damping can be represented by an equivalent mechanical vibration absorber with a spring, dashpot, and inerter in series. A common calibration procedure for multiple electromechanical shunt absorbers is obtained by this equivalence, including a correction for the influence from residual vibration modes by additional modal terms, whose coefficients are consistently identified by frequency matching for the system with rigid absorber dashpots. The accuracy and robustness of the calibration procedure are verified numerically for an unsupported truss structure with rigid body modes
    Original languageEnglish
    JournalJournal of Vibration and Control
    Volume26
    Issue number13-14
    Pages (from-to)1133–1144
    ISSN1077-5463
    DOIs
    Publication statusPublished - 2020

    Keywords

    • Vibrations
    • Electromagnetic
    • Piezoelectric
    • Shunt damping
    • Cibration absorber
    • Modal analysis

    Fingerprint

    Dive into the research topics of 'Consistent frequency-matching calibration procedure for electromechanical shunt absorbers'. Together they form a unique fingerprint.