Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography

Jixin Qiao, Yihong Xu, Xiaolin Hou, Manuel Miró

    Research output: Contribution to journalJournal articleResearchpeer-review

    Abstract

    This paper describes improvement and comparison of analytical methods for simultaneous determination of trace-level plutonium and neptunium in urine samples by inductively coupled plasma mass spectrometry (ICP-MS). Four sample pre-concentration techniques, including calcium phosphate, iron hydroxide and manganese dioxide co-precipitation and evaporation were compared and the applicability of different techniques was discussed in order to evaluate and establish the optimal method for in vivo radioassay program. The analytical results indicate that the various sample pre-concentration approaches afford dissimilar method performances and care should be taken for specific experimental parameters for improving chemical yields. The best analytical performances in terms of turnaround time (6 h) and chemical yields for plutonium (88.7 +/- 11.6%) and neptunium (94.2 +/- 2.0%) were achieved by manganese dioxide co-precipitation. The need of drying ashing (>= 7 h) for calcium phosphate co-precipitation and long-term aging (5 d) for iron hydroxide co-precipitation, respectively, rendered time-consuming analytical protocols. Despite the fact that evaporation is also somewhat time-consuming (1.5 d), it endows urinalysis methods with better reliability and repeatability compared with co-precipitation techniques. In view of the applicability of different pre-concentration techniques proposed previously in the literature, the main challenge behind relevant method development is pointed to be the release of plutonium and neptunium associated with organic compounds in real urine assays. In this work, different protocols for decomposing organic matter in urine were investigated, of which potassium persulfate (K2S2O8) treatment provided the highest chemical yield of neptunium in the iron hydroxide co-precipitation step, yet, the occurrence of sulfur compounds in the processed sample deteriorated the analytical performance of the ensuing extraction chromatographic separation with chemical yields of
    Original languageEnglish
    JournalTalanta
    Volume128
    Pages (from-to)75-82
    Number of pages8
    ISSN0039-9140
    DOIs
    Publication statusPublished - 2014

    Keywords

    • chemical yield
    • calcium phosphate 10103-46-5
    • iron hydroxide 11113-66-9
    • manganese dioxide 1313-13-9
    • neptunium 7439-99-8
    • plutonium 7440-07-5
    • potassium persulfate 7727-21-1
    • sulfur 7704-34-9
    • 10060, Biochemistry studies - General
    • 10069, Biochemistry studies - Minerals
    • 15504, Urinary system - Physiology and biochemistry
    • urine excretory system
    • automatic extraction chromatography laboratory techniques, chromatographic techniques
    • in vivo radioassay laboratory techniques
    • inductively coupled plasma mass spectrometry ICP-MS laboratory techniques, spectrum analysis techniques
    • urinalysis method laboratory techniques
    • Biochemistry and Molecular Biophysics
    • Methods and Techniques
    • CHEMISTRY,
    • PLASMA-MASS SPECTROMETRY
    • ALPHA-SPECTROMETRY
    • URINE MATRIX
    • INTRODUCTION SYSTEM
    • RAPID-DETERMINATION
    • ANION-EXCHANGE
    • ICP-MS
    • SEPARATION
    • ACTINIDES
    • ISOTOPES
    • Plutonium
    • Neptunium
    • Urine
    • Pre-concentration techniques
    • Lab-on-valve extraction chromatography

    Fingerprint

    Dive into the research topics of 'Comparison of sample preparation methods for reliable plutonium and neptunium urinalysis using automatic extraction chromatography'. Together they form a unique fingerprint.

    Cite this