Comparison of Blackbodies for Calibration of Infrared Ear Thermometers

Research output: Contribution to journalJournal article – Annual report year: 2011Researchpeer-review

Standard

Comparison of Blackbodies for Calibration of Infrared Ear Thermometers. / Pušnik, Igor; Clausen, Sønnik; Favreau, Jacques-Olivier; Gutschwager, Berndt; Dogan, Aliye Kartal; Diril, Ahmet; Guven, Ozlem Pehlivan; McEvoy, Helen; Hoem, Stian Samset; Steiner, Anton; van der Ham, Eric.

In: International Journal of Thermophysics, Vol. 32, No. 1-2, 01.2011, p. 127-138.

Research output: Contribution to journalJournal article – Annual report year: 2011Researchpeer-review

Harvard

Pušnik, I, Clausen, S, Favreau, J-O, Gutschwager, B, Dogan, AK, Diril, A, Guven, OP, McEvoy, H, Hoem, SS, Steiner, A & van der Ham, E 2011, 'Comparison of Blackbodies for Calibration of Infrared Ear Thermometers', International Journal of Thermophysics, vol. 32, no. 1-2, pp. 127-138. https://doi.org/10.1007/s10765-011-0928-8

APA

Pušnik, I., Clausen, S., Favreau, J-O., Gutschwager, B., Dogan, A. K., Diril, A., ... van der Ham, E. (2011). Comparison of Blackbodies for Calibration of Infrared Ear Thermometers. International Journal of Thermophysics, 32(1-2), 127-138. https://doi.org/10.1007/s10765-011-0928-8

CBE

Pušnik I, Clausen S, Favreau J-O, Gutschwager B, Dogan AK, Diril A, Guven OP, McEvoy H, Hoem SS, Steiner A, van der Ham E. 2011. Comparison of Blackbodies for Calibration of Infrared Ear Thermometers. International Journal of Thermophysics. 32(1-2):127-138. https://doi.org/10.1007/s10765-011-0928-8

MLA

Vancouver

Author

Pušnik, Igor ; Clausen, Sønnik ; Favreau, Jacques-Olivier ; Gutschwager, Berndt ; Dogan, Aliye Kartal ; Diril, Ahmet ; Guven, Ozlem Pehlivan ; McEvoy, Helen ; Hoem, Stian Samset ; Steiner, Anton ; van der Ham, Eric. / Comparison of Blackbodies for Calibration of Infrared Ear Thermometers. In: International Journal of Thermophysics. 2011 ; Vol. 32, No. 1-2. pp. 127-138.

Bibtex

@article{f979a6ea97854e13b4a94978d5190c04,
title = "Comparison of Blackbodies for Calibration of Infrared Ear Thermometers",
abstract = "The article presents the results of the EURAMET Project No. 927 “Comparison of blackbodies for calibration of infrared ear thermometers (IRETs)”. The objective of the comparison was to determine the agreement of blackbodies used for the calibration of IRETs among European national laboratories. To verify the accuracy of an IRET, a suitable blackbody (BB) is needed. Such a blackbody related to the EN standard, designed for the calibration of ear thermometers and immersed in a stirred water bath, was provided for the comparison by the pilot laboratory. The pilot provided also the transfer IRET and organized the comparison.",
keywords = "Combustion pollution control technologies, Accuracy, Blackbody, Ear thermometer, Uncertainty, Forbr{\ae}nding milj{\o}forbedrende teknologier",
author = "Igor Pušnik and S{\o}nnik Clausen and Jacques-Olivier Favreau and Berndt Gutschwager and Dogan, {Aliye Kartal} and Ahmet Diril and Guven, {Ozlem Pehlivan} and Helen McEvoy and Hoem, {Stian Samset} and Anton Steiner and {van der Ham}, Eric",
year = "2011",
month = "1",
doi = "10.1007/s10765-011-0928-8",
language = "English",
volume = "32",
pages = "127--138",
journal = "International Journal of Thermophysics",
issn = "0195-928X",
publisher = "Springer New York",
number = "1-2",

}

RIS

TY - JOUR

T1 - Comparison of Blackbodies for Calibration of Infrared Ear Thermometers

AU - Pušnik, Igor

AU - Clausen, Sønnik

AU - Favreau, Jacques-Olivier

AU - Gutschwager, Berndt

AU - Dogan, Aliye Kartal

AU - Diril, Ahmet

AU - Guven, Ozlem Pehlivan

AU - McEvoy, Helen

AU - Hoem, Stian Samset

AU - Steiner, Anton

AU - van der Ham, Eric

PY - 2011/1

Y1 - 2011/1

N2 - The article presents the results of the EURAMET Project No. 927 “Comparison of blackbodies for calibration of infrared ear thermometers (IRETs)”. The objective of the comparison was to determine the agreement of blackbodies used for the calibration of IRETs among European national laboratories. To verify the accuracy of an IRET, a suitable blackbody (BB) is needed. Such a blackbody related to the EN standard, designed for the calibration of ear thermometers and immersed in a stirred water bath, was provided for the comparison by the pilot laboratory. The pilot provided also the transfer IRET and organized the comparison.

AB - The article presents the results of the EURAMET Project No. 927 “Comparison of blackbodies for calibration of infrared ear thermometers (IRETs)”. The objective of the comparison was to determine the agreement of blackbodies used for the calibration of IRETs among European national laboratories. To verify the accuracy of an IRET, a suitable blackbody (BB) is needed. Such a blackbody related to the EN standard, designed for the calibration of ear thermometers and immersed in a stirred water bath, was provided for the comparison by the pilot laboratory. The pilot provided also the transfer IRET and organized the comparison.

KW - Combustion pollution control technologies

KW - Accuracy

KW - Blackbody

KW - Ear thermometer

KW - Uncertainty

KW - Forbrænding miljøforbedrende teknologier

U2 - 10.1007/s10765-011-0928-8

DO - 10.1007/s10765-011-0928-8

M3 - Journal article

VL - 32

SP - 127

EP - 138

JO - International Journal of Thermophysics

JF - International Journal of Thermophysics

SN - 0195-928X

IS - 1-2

ER -