Clinical Comparison of Pulse and Chirp Excitation

    Research output: Chapter in Book/Report/Conference proceeding › Article in proceedings › Research › peer-review

    583 Downloads (Orbit)

    Abstract

    Coded excitation (CE) using frequency modulated signals (chirps) combined with modified matched filtering has earlier been presented showing promising results in simulations and in-vitro. In this study an experimental ultrasound system is evaluated in a clinical setting, where image sequences are assessed by skilled medical doctors. The effect on penetration depth and image quality were measured. A modified clinical scanner with a 4 MHz single element mechanical transducer, and external transmitter and receiver boards (RASMUS system) were used. The system allowed rapid toggling between chirp and short pulse excitation to simultaneously produce identical image sequences using both techniques. Nine healthy male volunteers were scanned in abdominal locations. All sequences were evaluated by 3 skilled medical doctors, blinded to each other and to the technique used. They assessed the depth (1) in which image quality decreased and (2) in which the image would be insufficient for clinical diagnosis. Furthermore they compared image quality in matching pairs of conventional and CE images. The average increase in penetration depth were almost 2 cm. Side-by-side comparison showed that coded image quality was consistently rated better; significant (p≤0.05) when images were cropped at minimum the depth for good image quality and highly significant (p
    Original languageEnglish
    Title of host publicationIEEE Ultrasonics Symposium, 2002. Proceedings
    PublisherIEEE
    Publication date2002
    Pages1632-1635
    ISBN (Print)0-7803-7582-3
    DOIs
    Publication statusPublished - 2002
    Event2002 IEEE Ultrasonics Symposium - Munich, Germany
    Duration: 8 Oct 2002 → 11 Oct 2002
    http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8480

    Conference

    Conference2002 IEEE Ultrasonics Symposium
    Country/TerritoryGermany
    CityMunich
    Period08/10/2002 → 11/10/2002
    Internet address

    Bibliographical note

    Copyright: 2002 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE

    Fingerprint

    Dive into the research topics of 'Clinical Comparison of Pulse and Chirp Excitation'. Together they form a unique fingerprint.

    Cite this