Clinical Comparison of Pulse and Chirp Excitation

Morten Høgholm Pedersen, T. Misaridis, Jørgen Arendt Jensen

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

288 Downloads (Pure)

Abstract

Coded excitation (CE) using frequency modulated signals (chirps) combined with modified matched filtering has earlier been presented showing promising results in simulations and in-vitro. In this study an experimental ultrasound system is evaluated in a clinical setting, where image sequences are assessed by skilled medical doctors. The effect on penetration depth and image quality were measured. A modified clinical scanner with a 4 MHz single element mechanical transducer, and external transmitter and receiver boards (RASMUS system) were used. The system allowed rapid toggling between chirp and short pulse excitation to simultaneously produce identical image sequences using both techniques. Nine healthy male volunteers were scanned in abdominal locations. All sequences were evaluated by 3 skilled medical doctors, blinded to each other and to the technique used. They assessed the depth (1) in which image quality decreased and (2) in which the image would be insufficient for clinical diagnosis. Furthermore they compared image quality in matching pairs of conventional and CE images. The average increase in penetration depth were almost 2 cm. Side-by-side comparison showed that coded image quality was consistently rated better; significant (p≤0.05) when images were cropped at minimum the depth for good image quality and highly significant (p
Original languageEnglish
Title of host publicationIEEE Ultrasonics Symposium, 2002. Proceedings
PublisherIEEE
Publication date2002
Pages1632-1635
ISBN (Print)0-7803-7582-3
DOIs
Publication statusPublished - 2002
Event2002 IEEE Ultrasonics Symposium - Munich, Germany
Duration: 8 Oct 200211 Oct 2002
http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8480

Conference

Conference2002 IEEE Ultrasonics Symposium
CountryGermany
CityMunich
Period08/10/200211/10/2002
Internet address

Bibliographical note

Copyright: 2002 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE

Fingerprint Dive into the research topics of 'Clinical Comparison of Pulse and Chirp Excitation'. Together they form a unique fingerprint.

Cite this