Carbon-10: Example of cyclotron production of positron emitters as an open research field

F. Alves, J.J.P. Lima, R.J. Nickles, Mikael Jensen

    Research output: Contribution to journalJournal articleResearchpeer-review

    Abstract

    This paper supports the thesis that significant improvement of PET output response to clinical questions can be achieved by innovation in radionuclide production. Moreover, that development can be performed with the resources available at a clinical centre. Carbon-10 production parameters studies are used as example. A technical methodology for measurement of excitation function of nuclear reactions yielding short-lived radionuclides, performed to measure cross section values of the B-10(p,n)C-10 reaction in a PET-devoted cyclotron, is presented. (c) 2006 Elsevier Ltd. All rights reserved.
    Original languageEnglish
    JournalRadiation Physics and Chemistry
    Volume76
    Issue number2
    Pages (from-to)343-346
    ISSN0969-806X
    DOIs
    Publication statusPublished - 2007