Calibration of modified parallel-plate rheometer through calibrated oil and lattice Boltzmann simulation

Chiara F Ferraris, Mette Rica Geiker, Nicos S Martys, Nicholas Muzzatti

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    Abstract

    Fluid flow patterns in traditional rotational rheometers are generally well known so that rheological parameters such as viscosity can be easily calculated from experimental data of single phase fluids and analytical solutions of the flow patterns. However, when the fluid is a suspension, where some of the particles are as large as 2 mm in diameter, these rheometers may need to be modified. The distance between the shearing planes needs to be increased, which necessitates additional physical confinement of the fluid. The inclusion of a confining wall makes current analytical solutions inapplicable here. This paper presents the analysis of a modified parallel plate rheometer for measuring cement mortar and propose a methodology for calibration using standard oils and numerical simulation of the flow. A lattice Boltzmann method was used to simulate the flow in the modified rheometer, thus using an accurate numerical solution in place of the intractable analytical solution. The simulations reproduced experimental results by taking into account the actual rheometer geometry. The numerical simulations showed that small changes in the rheometer design can have a significant impact on how the rheological data should be extracted from the experimental results.
    Original languageEnglish
    Title of host publicationSelf-Compacting Concrete SCC 2007 : Proceedings of the Fifth International Symposium
    Number of pages1055
    Volume1
    Place of PublicationFrance
    PublisherRilem publications
    Publication date2007
    Edition1
    Pages297-302
    ISBN (Print)978-2-35158-050-9
    Publication statusPublished - 2007
    Event5th International Symposium on Self-Compacting Concrete - Ghent, Belgium
    Duration: 3 Sept 20075 Sept 2007
    Conference number: 5
    http://www.rilem.net/gene/main.php?base=500218&id_publication=59

    Conference

    Conference5th International Symposium on Self-Compacting Concrete
    Number5
    Country/TerritoryBelgium
    CityGhent
    Period03/09/200705/09/2007
    Internet address

    Keywords

    • Rheology, rheometer calibration, mortar rheometer

    Fingerprint

    Dive into the research topics of 'Calibration of modified parallel-plate rheometer through calibrated oil and lattice Boltzmann simulation'. Together they form a unique fingerprint.

    Cite this