Calibration of ground-based lidar instrument WLS7-204

Research output: Book/ReportReport

Abstract

This report presents the result of the lidar calibration performed for the given WLS7 Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.
Original languageEnglish
PublisherDTU Wind Energy
Number of pages28
Publication statusPublished - 2012
SeriesDTU Wind Energy LC I
Number005

Bibliographical note

This is an internal report and therefore not available in full text. Please contact author's or director of author's institute for further information.

Keywords

  • DTU Wind Energy LC I-005(EN)
  • LC-I-005
  • LC-I-005(EN)

Cite this

Gómez Arranz, Paula ; Courtney, Michael. / Calibration of ground-based lidar instrument WLS7-204. DTU Wind Energy, 2012. 28 p. (DTU Wind Energy LC I; No. 005).
@book{e78a533c8bda40b2a65c6392e6e53aea,
title = "Calibration of ground-based lidar instrument WLS7-204",
abstract = "This report presents the result of the lidar calibration performed for the given WLS7 Windcube at DTU’s test site for large wind turbine at H{\o}vs{\o}re, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.",
keywords = "DTU Wind Energy LC I-005(EN), LC-I-005, LC-I-005(EN)",
author = "{G{\'o}mez Arranz}, Paula and Michael Courtney",
note = "This is an internal report and therefore not available in full text. Please contact author's or director of author's institute for further information.",
year = "2012",
language = "English",
publisher = "DTU Wind Energy",
address = "Denmark",

}

Gómez Arranz, P & Courtney, M 2012, Calibration of ground-based lidar instrument WLS7-204. DTU Wind Energy LC I, no. 005, DTU Wind Energy.

Calibration of ground-based lidar instrument WLS7-204. / Gómez Arranz, Paula; Courtney, Michael.

DTU Wind Energy, 2012. 28 p. (DTU Wind Energy LC I; No. 005).

Research output: Book/ReportReport

TY - RPRT

T1 - Calibration of ground-based lidar instrument WLS7-204

AU - Gómez Arranz, Paula

AU - Courtney, Michael

N1 - This is an internal report and therefore not available in full text. Please contact author's or director of author's institute for further information.

PY - 2012

Y1 - 2012

N2 - This report presents the result of the lidar calibration performed for the given WLS7 Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.

AB - This report presents the result of the lidar calibration performed for the given WLS7 Windcube at DTU’s test site for large wind turbine at Høvsøre, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.

KW - DTU Wind Energy LC I-005(EN)

KW - LC-I-005

KW - LC-I-005(EN)

M3 - Report

BT - Calibration of ground-based lidar instrument WLS7-204

PB - DTU Wind Energy

ER -

Gómez Arranz P, Courtney M. Calibration of ground-based lidar instrument WLS7-204. DTU Wind Energy, 2012. 28 p. (DTU Wind Energy LC I; No. 005).