Calibration of Ground-based Lidar instrument

Research output: Book/ReportReport

Abstract

This report presents the result of the lidar calibration performed for the given Ground-based Lidar at DTU’s test site for large wind turbines at Østerild, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.
Original languageEnglish
PublisherDTU Wind Energy
Number of pages29
Publication statusPublished - 2019
SeriesDTU Wind Energy I
NumberLC I-142

Bibliographical note

This is an internal report and therefore not available in full text. Please contact author's or director of author's department for further information.

Keywords

  • LC I-142

Cite this

Villanueva, H., & Gómez Arranz, P. (2019). Calibration of Ground-based Lidar instrument. DTU Wind Energy. DTU Wind Energy I, No. LC I-142
Villanueva, Héctor ; Gómez Arranz, Paula. / Calibration of Ground-based Lidar instrument. DTU Wind Energy, 2019. 29 p. (DTU Wind Energy I; No. LC I-142).
@book{d1439407eeac4e7bbc1dce5d1d01e481,
title = "Calibration of Ground-based Lidar instrument",
abstract = "This report presents the result of the lidar calibration performed for the given Ground-based Lidar at DTU’s test site for large wind turbines at {\O}sterild, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.",
keywords = "LC I-142",
author = "H{\'e}ctor Villanueva and {G{\'o}mez Arranz}, Paula",
note = "This is an internal report and therefore not available in full text. Please contact author's or director of author's department for further information.",
year = "2019",
language = "English",
series = "DTU Wind Energy I",
number = "LC I-142",
publisher = "DTU Wind Energy",
address = "Denmark",

}

Villanueva, H & Gómez Arranz, P 2019, Calibration of Ground-based Lidar instrument. DTU Wind Energy I, no. LC I-142, DTU Wind Energy.

Calibration of Ground-based Lidar instrument. / Villanueva, Héctor; Gómez Arranz, Paula.

DTU Wind Energy, 2019. 29 p. (DTU Wind Energy I; No. LC I-142).

Research output: Book/ReportReport

TY - RPRT

T1 - Calibration of Ground-based Lidar instrument

AU - Villanueva, Héctor

AU - Gómez Arranz, Paula

N1 - This is an internal report and therefore not available in full text. Please contact author's or director of author's department for further information.

PY - 2019

Y1 - 2019

N2 - This report presents the result of the lidar calibration performed for the given Ground-based Lidar at DTU’s test site for large wind turbines at Østerild, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.

AB - This report presents the result of the lidar calibration performed for the given Ground-based Lidar at DTU’s test site for large wind turbines at Østerild, Denmark. Calibration is here understood as the establishment of a relation between the reference wind speed measurements with measurement uncertainties provided by measurement standard and corresponding lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from wind vanes measurements are given for information only.

KW - LC I-142

M3 - Report

T3 - DTU Wind Energy I

BT - Calibration of Ground-based Lidar instrument

PB - DTU Wind Energy

ER -

Villanueva H, Gómez Arranz P. Calibration of Ground-based Lidar instrument. DTU Wind Energy, 2019. 29 p. (DTU Wind Energy I; No. LC I-142).