The asymptotic distribution of the total time spent in the down state in an interval is derived for a 2-unit cold-standby system with a single repair facility. The time to failure of the working unit is exponentially distributed and the distribution of the repair time is arbitrary.
Original language | English |
---|---|
Journal | I E E E Transactions on Reliability |
Volume | 29 |
Issue number | 1 |
Pages (from-to) | 79-81 |
ISSN | 0018-9529 |