    Abstract

    Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence from urine. As this green fluorescence confounds the desired red fluorescence of the PDD, methods for avoiding this situation particularly in cystoscopy using flexible cystoscopes are desirable. In this paper we demonstrate how a tailor made high power LED light source at 525 nm can be used for fluorescence assisted tumour detection using both a flexible and rigid cystoscope used in the outpatient department (OPD) and operating room (OR) respectively. It is demonstrated both in vitro and in vivo how this light source can significantly reduce the green fluorescence problem with urine. At the same time this light source also is useful for exciting autofluorescence in healthy bladder mucosa. This autofluorescence then provides a contrast to the sensitized fluorescence (PDD) of tumours in the bladder.
    Original languageEnglish
    Article number045002
    JournalMethods and Applications in Fluorescence
    Volume4
    Issue number4
    ISSN2050-6120
    DOIs
    Publication statusPublished - 2016

    Cite this

    @article{9f5cd5f12d5243fdb68961795f9d3a6f,
    title = "An optical method for reducing green fluorescence from urine during fluorescence-guided cystoscopy",
    abstract = "Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence from urine. As this green fluorescence confounds the desired red fluorescence of the PDD, methods for avoiding this situation particularly in cystoscopy using flexible cystoscopes are desirable. In this paper we demonstrate how a tailor made high power LED light source at 525 nm can be used for fluorescence assisted tumour detection using both a flexible and rigid cystoscope used in the outpatient department (OPD) and operating room (OR) respectively. It is demonstrated both in vitro and in vivo how this light source can significantly reduce the green fluorescence problem with urine. At the same time this light source also is useful for exciting autofluorescence in healthy bladder mucosa. This autofluorescence then provides a contrast to the sensitized fluorescence (PDD) of tumours in the bladder.",
    author = "Lindvold, {Lars Ren{\'e}} and Hermann, {Gregers G}",
    year = "2016",
    doi = "10.1088/2050-6120/4/4/045002",
    language = "English",
    volume = "4",
    journal = "Methods and Applications in Fluorescence",
    issn = "2050-6120",
    publisher = "IOP Publishing",
    number = "4",

    }

    An optical method for reducing green fluorescence from urine during fluorescence-guided cystoscopy. / Lindvold, Lars René; Hermann, Gregers G.

    In: Methods and Applications in Fluorescence, Vol. 4, No. 4, 045002, 2016.

    Research output: Contribution to journalJournal articleResearchpeer-review

    TY - JOUR

    T1 - An optical method for reducing green fluorescence from urine during fluorescence-guided cystoscopy

    AU - Lindvold, Lars René

    AU - Hermann, Gregers G

    PY - 2016

    Y1 - 2016

    N2 - Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence from urine. As this green fluorescence confounds the desired red fluorescence of the PDD, methods for avoiding this situation particularly in cystoscopy using flexible cystoscopes are desirable. In this paper we demonstrate how a tailor made high power LED light source at 525 nm can be used for fluorescence assisted tumour detection using both a flexible and rigid cystoscope used in the outpatient department (OPD) and operating room (OR) respectively. It is demonstrated both in vitro and in vivo how this light source can significantly reduce the green fluorescence problem with urine. At the same time this light source also is useful for exciting autofluorescence in healthy bladder mucosa. This autofluorescence then provides a contrast to the sensitized fluorescence (PDD) of tumours in the bladder.

    AB - Photodynamic diagnosis (PDD) of bladder tumour tissue significantly improves endoscopic diagnosis and treatment of bladder cancer in rigid cystoscopes in the operating theatre and thus reduces tumour recurrence. PDD comprises the use of blue light, which unfortunately excites green fluorescence from urine. As this green fluorescence confounds the desired red fluorescence of the PDD, methods for avoiding this situation particularly in cystoscopy using flexible cystoscopes are desirable. In this paper we demonstrate how a tailor made high power LED light source at 525 nm can be used for fluorescence assisted tumour detection using both a flexible and rigid cystoscope used in the outpatient department (OPD) and operating room (OR) respectively. It is demonstrated both in vitro and in vivo how this light source can significantly reduce the green fluorescence problem with urine. At the same time this light source also is useful for exciting autofluorescence in healthy bladder mucosa. This autofluorescence then provides a contrast to the sensitized fluorescence (PDD) of tumours in the bladder.

    U2 - 10.1088/2050-6120/4/4/045002

    DO - 10.1088/2050-6120/4/4/045002

    M3 - Journal article

    VL - 4

    JO - Methods and Applications in Fluorescence

    JF - Methods and Applications in Fluorescence

    SN - 2050-6120

    IS - 4

    M1 - 045002