TY - RPRT
T1 - An approach to Kidney parameter identification by digital computer curve fitting of radiorenograms
AU - Højberg, Kristian Søe
PY - 1972
Y1 - 1972
N2 - The renogram test involved includes detection over the heart region, the kidneys, and the bladder after injection of radiohippuran. The external system as well ad the kidneys are simpulated by means of two-compartment models. The bladder is reperesented by one compartment. The compartment parameters are determined by curve fitting of the model and patient renograms. The background contribution from the blood circulation system, to the bladder and the kidney detectors, is subtracted.
AB - The renogram test involved includes detection over the heart region, the kidneys, and the bladder after injection of radiohippuran. The external system as well ad the kidneys are simpulated by means of two-compartment models. The bladder is reperesented by one compartment. The compartment parameters are determined by curve fitting of the model and patient renograms. The background contribution from the blood circulation system, to the bladder and the kidney detectors, is subtracted.
KW - Risø-M-1514
M3 - Report
T3 - Risø-M
BT - An approach to Kidney parameter identification by digital computer curve fitting of radiorenograms
PB - Risø National Laboratory
CY - Roskilde, Denmark
ER -