An application of LTR design in fault detection

    Research output: Contribution to journalJournal articleResearchpeer-review

    Abstract

    The fault detection and isolation (FDI) problem is considered in this paper. The FDI problem is formulated as a filter design problem, where the faults in the system is estimated and the disturbance acting on the system is rejected. It turns out that the filter design problem can be considered as a standard Loop Transfer Recovery (LTR) design problem. As a consequence of the connection between LTR and FDI design, it is shown in an example how the LQG/LTR design method for full order and a proportional-integral observer can be applied with advantages in connection with FDI.
    Original languageEnglish
    JournalOptimal Control Application and Methods
    Volume19
    Pages (from-to)215-225
    Publication statusPublished - 1998