Active fault diagnosis in closed-loop uncertain systems

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Abstract

Fault diagnosis of parametric faults in closed-loop uncertain systems by using an auxiliary input vector is considered in this paper, i.e. active fault diagnosis (AFD). The active fault diagnosis is based directly on the socalled fault signature matrix, related to the YJBK (Youla, Jabr, Bongiorno and Kucera) parameterization. Conditions are given for exact detection and isolation of parametric faults in closed-loop uncertain systems.
Original languageEnglish
Title of host publicationProceedings of the 6th IFAC Symposium on Fault Detection Supervision ans Safety for Technical Processes, SAFEPROCESS'2006
Publication date2006
Pages631-636
Publication statusPublished - 2006
Event6th IFAC Symposium on Fault Detection Supervision and Safety for Technical Processes - Beijing, China
Duration: 30 Aug 20061 Sep 2006
Conference number: 6
http://safeprocess2012.unam.mx/History.html

Conference

Conference6th IFAC Symposium on Fault Detection Supervision and Safety for Technical Processes
Number6
CountryChina
CityBeijing
Period30/08/200601/09/2006
Internet address

Fingerprint Dive into the research topics of 'Active fault diagnosis in closed-loop uncertain systems'. Together they form a unique fingerprint.

Cite this