Abstract
Fault diagnosis of parametric faults in closed-loop uncertain systems
by using an auxiliary input vector is considered in this paper,
i.e. active fault diagnosis (AFD). The active fault diagnosis is based
directly on the socalled fault signature matrix, related to the
YJBK (Youla, Jabr, Bongiorno and Kucera) parameterization. Conditions
are given for exact detection and isolation of parametric faults in closed-loop uncertain systems.
Original language | English |
---|---|
Title of host publication | Proceedings of the 6th IFAC Symposium on Fault Detection Supervision ans Safety for Technical Processes, SAFEPROCESS'2006 |
Publication date | 2006 |
Pages | 631-636 |
Publication status | Published - 2006 |
Event | 6th IFAC Symposium on Fault Detection Supervision and Safety for Technical Processes - Beijing, China Duration: 30 Aug 2006 → 1 Sept 2006 Conference number: 6 http://safeprocess2012.unam.mx/History.html |
Conference
Conference | 6th IFAC Symposium on Fault Detection Supervision and Safety for Technical Processes |
---|---|
Number | 6 |
Country/Territory | China |
City | Beijing |
Period | 30/08/2006 → 01/09/2006 |
Internet address |