Abstract
For an ongoing elevated-source, urban-scale tracer experiment, an instrument system to measure the three-dimensional wind velocity and the turbulent sensible heat flux was developed. The wind velocity was measured with a combination of cup anemometer, propeller (vertical) and vane sensor. The temperature fluctuations were derived using a uniquely referenced thermocouple pair. The temperature sensor is described in detail. The wind sensors have already been described elsewhere
| Original language | English |
|---|---|
| Journal | Journal of Applied Meteorology |
| Volume | 18 |
| Issue number | 12 |
| Pages (from-to) | 1674-1678 |
| Publication status | Published - 1979 |
Fingerprint
Dive into the research topics of 'A Tall-Tower Instrument for Mean and Fluctuating Velocity, Fluctuating Temperature and Sensible Heat Flux Measurements'. Together they form a unique fingerprint.Cite this