T1 - A single-blind field intervention study of whether increased bedroom ventilation improves sleep quality
AU - Fan, Xiaojun
AU - Liao, Chenxi
AU - Matsuo, Kazuya
AU - Verniers, Kevin
AU - Laverge, Jelle
AU - Neyrinck, Brecht
AU - Pollet, Ivan
AU - Fang, Lei
AU - Lan, Li
AU - Sekhar, Chandra
AU - Wargocki, Pawel
PY - 2023
Y1 - 2023
N2 - A four-week-long field intervention experiment was conducted in twenty-nine bedrooms with extract ventilation systems and air inlet vents. During the first week no interventions took place. In the three weeks that followed, each participant slept for one week under a low, medium, and high ventilation rate condition in a balanced order. These conditions were established by covertly altering the fan speed of the exhaust ventilation system without changing other settings. Participants were not informed when or even whether the changes to bedroom ventilation would be executed. The bedroom environmental quality was monitored continuously and sleep quality was monitored using wrist-worn trackers. Tests of cognitive performance were conducted in the evening and morning. In twelve bedrooms where clear differences between the three ventilation conditions occurred, as indicated by the measured CO2 concentrations, participants had significantly less deep sleep, more light sleep and more awakenings at lower ventilation rate conditions. In twenty-three bedrooms where a clear difference in ventilation rate between the high and low ventilation conditions was observed, as confirmed by the measured CO2 concentrations, the duration of deep sleep was significantly shorter in the low ventilation rate condition. No differences in cognitive performance between conditions were observed. At lower ventilation rate conditions, the concentrations of CO2 increased, as did the relative humidity, while bedroom temperatures remained unchanged. The present results, which were obtained in actual bedrooms, confirm the findings in previous studies of a positive effect of increased ventilation on sleep quality. Further studies with larger populations and better control of bedroom conditions, particularly ventilation, are required.
AB - A four-week-long field intervention experiment was conducted in twenty-nine bedrooms with extract ventilation systems and air inlet vents. During the first week no interventions took place. In the three weeks that followed, each participant slept for one week under a low, medium, and high ventilation rate condition in a balanced order. These conditions were established by covertly altering the fan speed of the exhaust ventilation system without changing other settings. Participants were not informed when or even whether the changes to bedroom ventilation would be executed. The bedroom environmental quality was monitored continuously and sleep quality was monitored using wrist-worn trackers. Tests of cognitive performance were conducted in the evening and morning. In twelve bedrooms where clear differences between the three ventilation conditions occurred, as indicated by the measured CO2 concentrations, participants had significantly less deep sleep, more light sleep and more awakenings at lower ventilation rate conditions. In twenty-three bedrooms where a clear difference in ventilation rate between the high and low ventilation conditions was observed, as confirmed by the measured CO2 concentrations, the duration of deep sleep was significantly shorter in the low ventilation rate condition. No differences in cognitive performance between conditions were observed. At lower ventilation rate conditions, the concentrations of CO2 increased, as did the relative humidity, while bedroom temperatures remained unchanged. The present results, which were obtained in actual bedrooms, confirm the findings in previous studies of a positive effect of increased ventilation on sleep quality. Further studies with larger populations and better control of bedroom conditions, particularly ventilation, are required.
KW - Bedroom air quality
KW - Mechanical extract ventilation
KW - Sleep quality
KW - Outdoor air supply rate
KW - Field intervention
U2 - 10.1016/j.scitotenv.2023.163805
DO - 10.1016/j.scitotenv.2023.163805
M3 - Journal article
C2 - 37142023
SN - 0048-9697
VL - 884
JO - Science of the Total Environment
JF - Science of the Total Environment
M1 - 163805
ER -