A new maximum likelihood blood velocity estimator incorporating spatial and temporal correlation

Malene Schlaikjer, Jørgen Arendt Jensen

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

250 Downloads (Pure)

Abstract

The blood flow in the human cardiovascular system obeys the laws of fluid mechanics. Investigation of the flow properties reveals that a correlation exists between the velocity in time and space. The possible changes in velocity are limited, since the blood velocity has a continuous profile in time and space. This paper presents a new estimator (STC-MLE), which incorporates the correlation property. It is an expansion of the maximum likelihood estimator (MLE) developed by Ferrara et al. With the MLE a cross-correlation analysis between consecutive RF-lines on complex form is carried out for a range of possible velocities. In the new estimator an additional similarity investigation for each evaluated velocity and the available velocity estimates in a temporal (between frames) and spatial (within frames) neighborhood is performed. An a priori probability density term in the distribution of the observations gives a probability measure of the correlation between the velocities. Both the MLE and the STC-MLE have been evaluated on simulated and in-vivo RF-data obtained from the carotid artery. Using the MLE 4.1% of the estimates deviate significantly from the true velocities, when the performance is evaluated on the simulated data. These deviating estimates arise, as the search range in the correlation analysis exceeds one wavelength. By performing a similar investigation with the STC-MLE, no highly deviating estimates occur. The allowed search range is therefore larger with the STC-MLE. The performance evaluation on in-vivo data further reveals that the number of highly deviating velocity estimates in the tissue parts of the RF-signals are reduced with the STC-MLE. In general the resulting profiles are continuous and more consistent with the true velocity profile, and the introduction of the correlation property has improved the estimates.
Original languageEnglish
Title of host publicationProceedings on IEEE Ultrasonics Symposium
Volume2
PublisherIEEE
Publication date2001
Pages1433-1437
ISBN (Print)0-7803-7177-1
DOIs
Publication statusPublished - 2001
Event2001 IEEE Ultrasonics Symposium - Atlanta, GA, United States
Duration: 7 Oct 200110 Oct 2001
http://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=7781

Conference

Conference2001 IEEE Ultrasonics Symposium
CountryUnited States
CityAtlanta, GA
Period07/10/200110/10/2001
Internet address

Bibliographical note

Copyright: 2000 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE

Fingerprint Dive into the research topics of 'A new maximum likelihood blood velocity estimator incorporating spatial and temporal correlation'. Together they form a unique fingerprint.

Cite this