Skip to main navigation Skip to search Skip to main content

A Data-driven Distance Metric for Evaluating the effects of Dynamic Range Compression in Adverse Conditions

Research output: Contribution to journalJournal articleResearchpeer-review

191 Downloads (Orbit)

Abstract

Dynamic range compression is a crucial component in hearing aids, aiming to restore audibility for hearing-impaired listeners. However, determining suitable compression parameters, such as the time constants for the level estimation stage, remains a topic of debate, as the perceptual benefit of different parameter configurations varies depending on the acoustic conditions. In this study, a data-driven distance metric based on physical metrics was developed to evaluate and compare the performance of various compression systems. This analysis encompassed fast-acting and slow-acting compression, as well as a “scene-aware” compression that dynamically adjusted the release time constant based on the presence of the target. A reference system called “source-independent compression” was also considered, which had access to individual speech and noise signals. Multiple physical metrics were employed to assess the effects of these different compression systems under diverse acoustic conditions, including varying levels of interfering noise and degrees of room reverberation. Factor analysis was applied to derive a concise set of interpretable features representing the impact of compression, expressed as linear combinations of carefully selected objective metrics. The reduced dimensional representation enabled the use of the Manhattan distance to measure the similarity between the compression systems. Results demonstrated that the scene-aware compressor generally exhibited a smaller distance to the reference system compared to both the fast-acting and slow-acting compressors. This finding suggests that an adaptive compression system holds potential benefits across a range of acoustic conditions.

Original languageEnglish
JournalTrends in Hearing
Volume27
Pages (from-to)1-12
ISSN2331-2165
DOIs
Publication statusPublished - 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Hearing aids
  • Objective metrics
  • Wide dynamic range compression

Fingerprint

Dive into the research topics of 'A Data-driven Distance Metric for Evaluating the effects of Dynamic Range Compression in Adverse Conditions'. Together they form a unique fingerprint.

Cite this