Transient Model Validation of Fixed-Speed Induction Generator Using Wind Farm Measurements
Publication: Research - peer-review › Journal article – Annual report year: 2012
Standard
Transient Model Validation of Fixed-Speed Induction Generator Using Wind Farm Measurements. / Rogdakis, Georgios; Garcia-Valle, Rodrigo; Arana Aristi, Iván.
In: I E E E Transactions on Power Systems, Vol. 27, No. 1, 2012, p. 564-571.Publication: Research - peer-review › Journal article – Annual report year: 2012
Harvard
APA
CBE
MLA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Transient Model Validation of Fixed-Speed Induction Generator Using Wind Farm Measurements
A1 - Rogdakis,Georgios
A1 - Garcia-Valle,Rodrigo
A1 - Arana Aristi,Iván
AU - Rogdakis,Georgios
AU - Garcia-Valle,Rodrigo
AU - Arana Aristi,Iván
PB - I E E E
PY - 2012
Y1 - 2012
N2 - In this paper, an electromagnetic transient model for fixed-speed wind turbines equipped with induction generators is developed and implemented in PSCAD/EMTDC. The model is comprised by: an induction generator, aerodynamic rotor, and a two-mass representation of the shaft system. Model validation is conducted by measurement comparison using recordings obtained from switching operations performed at the Nysted OffshoreWind Farm in Denmark. A sensitivity analysis is performed to determine the impact of different model parameters on the simulated response as compared with measurements. This validated model will be used for assessing induced overvoltage conditions that may arise under switching operations similar to those captured by the measurements used for validation.
AB - In this paper, an electromagnetic transient model for fixed-speed wind turbines equipped with induction generators is developed and implemented in PSCAD/EMTDC. The model is comprised by: an induction generator, aerodynamic rotor, and a two-mass representation of the shaft system. Model validation is conducted by measurement comparison using recordings obtained from switching operations performed at the Nysted OffshoreWind Farm in Denmark. A sensitivity analysis is performed to determine the impact of different model parameters on the simulated response as compared with measurements. This validated model will be used for assessing induced overvoltage conditions that may arise under switching operations similar to those captured by the measurements used for validation.
KW - Wind turbines
KW - Induction generators
KW - Current measurements
KW - Switching transient voltage measurements
KW - Modeling
U2 - 10.1109/TPWRS.2011.2168832
DO - 10.1109/TPWRS.2011.2168832
JO - I E E E Transactions on Power Systems
JF - I E E E Transactions on Power Systems
SN - 0885-8950
IS - 1
VL - 27
SP - 564
EP - 571
ER -