Subjective Response to Foot-Fall Noise, Including Localization of the Source Position
Publication: Research - peer-review › Journal article – Annual report year: 2011
Although an impact noise level is objectively evaluated the same
according to current standards, a lightweight floor structure is
often subjectively judged more annoying than a heavy homogeneous
structure. The hypothesis of the present investigation is
that the subjective judgment of impact noise is more annoying if
the source position can be localized; lightweight structures have
a more localized radiation than heavy structures. For the heavy
structures the reverberant vibration field is dominant, therefore
having a distributed radiation. A listening test is used to assess
the subjective annoyance, using simulated binaural room impulse
responses, with sources being a moving point source or a nonmoving
surface source, and rooms being a room with a reverberation
time of 0.5 s or an anechoic room. The paper concludes that
no strong effect of the source localization on the annoyance can
be found.
| Original language | English |
|---|---|
| Journal | Acustica United with Acta Acustica |
| Publication date | 2011 |
| Volume | 97 |
| Journal number | 5 |
| Pages | 904 - 908 |
| ISSN | 1610-1928 |
| DOIs | |
| State | Published |
| Citations | Web of Science® Times Cited: 0 |
|---|
ID: 5756216