Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2011

Standard

Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics. / Motosuke, Masahiro ; Jensen, Thomas Glasdam; Zhuang, Guisheng; Kutter, Jörg Peter.

Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. 2011. p. 1888-1890.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2011

Harvard

Motosuke, M, Jensen, TG, Zhuang, G & Kutter, JP 2011, 'Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics'. in Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. pp. 1888-1890.

APA

Motosuke, M., Jensen, T. G., Zhuang, G., & Kutter, J. P. (2011). Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics. In Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. (pp. 1888-1890)

CBE

Motosuke M, Jensen TG, Zhuang G, Kutter JP. 2011. Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics. In Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. pp. 1888-1890.

MLA

Motosuke, Masahiro et al. "Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics". Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. 2011. 1888-1890.

Vancouver

Motosuke M, Jensen TG, Zhuang G, Kutter JP. Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics. In Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. 2011. p. 1888-1890.

Author

Motosuke, Masahiro ; Jensen, Thomas Glasdam; Zhuang, Guisheng; Kutter, Jörg Peter / Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics.

Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences. 2011. p. 1888-1890.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2011

Bibtex

@inbook{b37ce10599594feb9f385afd9b03e24d,
title = "Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics",
author = "Masahiro Motosuke and Jensen, {Thomas Glasdam} and Guisheng Zhuang and Kutter, {Jörg Peter}",
year = "2011",
pages = "1888-1890",
booktitle = "Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences",

}

RIS

TY - GEN

T1 - Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics

A1 - Motosuke,Masahiro

A1 - Jensen,Thomas Glasdam

A1 - Zhuang,Guisheng

A1 - Kutter,Jörg Peter

AU - Motosuke,Masahiro

AU - Jensen,Thomas Glasdam

AU - Zhuang,Guisheng

AU - Kutter,Jörg Peter

PY - 2011

Y1 - 2011

N2 - A miniaturized flow cytometry incorporating both fluidic and optical systems has a great possibility for portable<br/>biochemical sensing or point-of-care diagnostics. This paper presents a simple microfluidic flow cytometer combining<br/>reliable 3D hydrodynamic focusing and optical detection without optical fibers in a monolithic architecture fabricated by a<br/>single photolithographic process. The vertical flow focusing is achieved by the optimized inlet geometry in a PDMS lid onto<br/>the substrate with detection channel and integrated optics. The simplified approach indicates the possibility to be applied as a<br/>portable platform of cytometer chip.

AB - A miniaturized flow cytometry incorporating both fluidic and optical systems has a great possibility for portable<br/>biochemical sensing or point-of-care diagnostics. This paper presents a simple microfluidic flow cytometer combining<br/>reliable 3D hydrodynamic focusing and optical detection without optical fibers in a monolithic architecture fabricated by a<br/>single photolithographic process. The vertical flow focusing is achieved by the optimized inlet geometry in a PDMS lid onto<br/>the substrate with detection channel and integrated optics. The simplified approach indicates the possibility to be applied as a<br/>portable platform of cytometer chip.

KW - Flow cytometry

KW - Hydrodynamic focusing

KW - Integrated optics

KW - Particle detection

BT - Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences

T2 - Proceedings of 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences

SP - 1888

EP - 1890

ER -