Nonlinear 3-D Microwave Imaging for Breast-Cancer Screening: Log, Phase, and Log-Phase Formulation
Publication: Research - peer-review › Article in proceedings – Annual report year: 2011
Standard
Nonlinear 3-D Microwave Imaging for Breast-Cancer Screening: Log, Phase, and Log-Phase Formulation. / Jensen, Peter Damsgaard; Rubæk, Tonny; Mohr, Johan Jacob; Zhurbenko, Vitaliy.
In: Loughborough Antennas & Propagation Conference: LAPC 2011. IEEE, 2011.Publication: Research - peer-review › Article in proceedings – Annual report year: 2011
Harvard
APA
CBE
MLA
Vancouver
Author
Bibtex
}
RIS
TY - GEN
T1 - Nonlinear 3-D Microwave Imaging for Breast-Cancer Screening: Log, Phase, and Log-Phase Formulation
A1 - Jensen,Peter Damsgaard
A1 - Rubæk,Tonny
A1 - Mohr,Johan Jacob
A1 - Zhurbenko,Vitaliy
AU - Jensen,Peter Damsgaard
AU - Rubæk,Tonny
AU - Mohr,Johan Jacob
AU - Zhurbenko,Vitaliy
PB - IEEE
PY - 2011
Y1 - 2011
N2 - The imaging algorithm used in the 3-D microwave imaging system for breast cancer screening, currently being developed at the Technical University of Denmark, is based on an iterative Newton-type algorithm. In this algorithm, the distribution of the electromagnetic constitutive parameters is updated in each iteration based on a comparison between the measured signals and the signals computed by a forward solver for the current parameter distribution. A key feature of the algorithm is the use of the log-phase formulation in which the measured complex signals are represented by the logarithm of their amplitudes and their unwrapped phases. In this paper, simplifications of the log-phase formulation are proposed, namely the log formulation, in which only the logarithm of the amplitudes are used, and the phase formulation, in which only the unwrapped phases are used. These formulations allow for the use of simpler tomographic systems in which only the amplitudes or the phases of the signals are measured. The performance of the algorithms using the two proposed formulations is investigated by reconstructing images of data collected with the above-mentioned imaging system, and the resulting images are compared with those obtained using the log-phase formulation.
AB - The imaging algorithm used in the 3-D microwave imaging system for breast cancer screening, currently being developed at the Technical University of Denmark, is based on an iterative Newton-type algorithm. In this algorithm, the distribution of the electromagnetic constitutive parameters is updated in each iteration based on a comparison between the measured signals and the signals computed by a forward solver for the current parameter distribution. A key feature of the algorithm is the use of the log-phase formulation in which the measured complex signals are represented by the logarithm of their amplitudes and their unwrapped phases. In this paper, simplifications of the log-phase formulation are proposed, namely the log formulation, in which only the logarithm of the amplitudes are used, and the phase formulation, in which only the unwrapped phases are used. These formulations allow for the use of simpler tomographic systems in which only the amplitudes or the phases of the signals are measured. The performance of the algorithms using the two proposed formulations is investigated by reconstructing images of data collected with the above-mentioned imaging system, and the resulting images are compared with those obtained using the log-phase formulation.
KW - Phase measurement
KW - Conductivity
KW - Vectors
KW - Antenna measurements
KW - Imaging
KW - Image reconstruction
KW - Permittivity
U2 - 10.1109/LAPC.2011.6114124
DO - 10.1109/LAPC.2011.6114124
SN - 9781457710148
BT - Loughborough Antennas & Propagation Conference
T2 - Loughborough Antennas & Propagation Conference
ER -