Monitoring and Control of a Continuous Grignard Reaction for the Synthesis of an Active Pharmaceutical Ingredient Intermediate Using Inline NIR spectroscopy
Publication: Research - peer-review › Journal article – Annual report year: 2012
Standard
Monitoring and Control of a Continuous Grignard Reaction for the Synthesis of an Active Pharmaceutical Ingredient Intermediate Using Inline NIR spectroscopy. / Cervera Padrell, Albert Emili; Nielsen, Jesper; Jønch Pedersen, Michael; Müller Christensen, Kim; Mortensen, Asmus R.; Skovby, Tommy; Dam-Johansen, Kim; Kiil, Søren; Gernaey, Krist V.
In: Organic Process Research and Development, Vol. 16, No. 5, 2012, p. 901-914.Publication: Research - peer-review › Journal article – Annual report year: 2012
Harvard
APA
CBE
MLA
Vancouver
Author
Bibtex
}
RIS
TY - JOUR
T1 - Monitoring and Control of a Continuous Grignard Reaction for the Synthesis of an Active Pharmaceutical Ingredient Intermediate Using Inline NIR spectroscopy
A1 - Cervera Padrell,Albert Emili
A1 - Nielsen,Jesper
A1 - Jønch Pedersen,Michael
A1 - Müller Christensen,Kim
A1 - Mortensen,Asmus R.
A1 - Skovby,Tommy
A1 - Dam-Johansen,Kim
A1 - Kiil,Søren
A1 - Gernaey,Krist V.
AU - Cervera Padrell,Albert Emili
AU - Nielsen,Jesper
AU - Jønch Pedersen,Michael
AU - Müller Christensen,Kim
AU - Mortensen,Asmus R.
AU - Skovby,Tommy
AU - Dam-Johansen,Kim
AU - Kiil,Søren
AU - Gernaey,Krist V.
PB - American Chemical Society
PY - 2012
Y1 - 2012
N2 - Inline near-infrared (NIR) spectroscopy has been used to monitor a continuous synthesis of an active pharmaceutical ingredient (API) intermediate by a Grignard alkylation reaction. The reaction between a ketone substrate and allylmagnesium chloride may form significant impurities with excess feeding of the Grignard reagent beyond the stoichiometric ratio. On the other hand, limiting this reagent would imply a loss in yield. Therefore, accurate dosing of the two reactants is essential. A feedforward–feedback control loop was conceived in order to maintain the reaction as closely as possible to the stoichiometric ratio, leading the path to full process automation. The feedback control loop relies on NIR transmission measurements performed in a flow cell where, in contrast to labor-intensive offline HPLC analytical methods, the whole reaction product can be scanned in real time without sample dilution. A robust PLS (projection to latent structures) model was developed with a satisfactory standard error of prediction, providing quantification of the ketone substrate in solutions with a high variability of the major solution component - the alkoxide product. In addition, model performance supervision tools such as the spectral residuals or simple plots of pretreated spectra can assist in the identification of spectral outliers, which in this case could be related to Grignard reagent excess. If the sampling time of the NIR instrument is short enough, manipulating the inputs to the reactor may be used to obtain information about its dynamic behavior. This information is very useful for process control design, assessment of analytical tools and definition of sampling times. In this work, a systematic procedure for chemometric model building is followed, after which a discussion is made on some of the potential applications that can be found when exploiting the fast and rich information provided by NIR spectroscopy.
AB - Inline near-infrared (NIR) spectroscopy has been used to monitor a continuous synthesis of an active pharmaceutical ingredient (API) intermediate by a Grignard alkylation reaction. The reaction between a ketone substrate and allylmagnesium chloride may form significant impurities with excess feeding of the Grignard reagent beyond the stoichiometric ratio. On the other hand, limiting this reagent would imply a loss in yield. Therefore, accurate dosing of the two reactants is essential. A feedforward–feedback control loop was conceived in order to maintain the reaction as closely as possible to the stoichiometric ratio, leading the path to full process automation. The feedback control loop relies on NIR transmission measurements performed in a flow cell where, in contrast to labor-intensive offline HPLC analytical methods, the whole reaction product can be scanned in real time without sample dilution. A robust PLS (projection to latent structures) model was developed with a satisfactory standard error of prediction, providing quantification of the ketone substrate in solutions with a high variability of the major solution component - the alkoxide product. In addition, model performance supervision tools such as the spectral residuals or simple plots of pretreated spectra can assist in the identification of spectral outliers, which in this case could be related to Grignard reagent excess. If the sampling time of the NIR instrument is short enough, manipulating the inputs to the reactor may be used to obtain information about its dynamic behavior. This information is very useful for process control design, assessment of analytical tools and definition of sampling times. In this work, a systematic procedure for chemometric model building is followed, after which a discussion is made on some of the potential applications that can be found when exploiting the fast and rich information provided by NIR spectroscopy.
UR - http://pubs.acs.org/doi/abs/10.1021/op2002563
U2 - 10.1021/op2002563
DO - 10.1021/op2002563
JO - Organic Process Research and Development
JF - Organic Process Research and Development
SN - 1083-6160
IS - 5
VL - 16
SP - 901
EP - 914
ER -