Medium to large scale radioisotope production for targeted radiotherapy using a small PET cyclotron

Publication: Research - peer-reviewJournal article – Annual report year: 2011

View graph of relations

In recent years the use of radionuclides in targeted cancer therapy has increased. In this study we have developed a high-current solid target system and demonstrated that by the use of a typical low-energy medical cyclotron, it is possible to produce tens of GBq's of many unconventional radionuclides relevant for cancer therapy such as 64Cu and 119Sb locally at the hospitals.
Original languageEnglish
JournalApplied Radiation and Isotopes
Publication date2011
Volume69
Issue1
Pages1-7
ISSN0969-8043
DOIs
StatePublished
CitationsWeb of Science® Times Cited: 11

Keywords

  • Sb-119, High powertarget, Radionuclide therapy, Cu-64, Auger electrons, DOTATATE