Implementation of Synthetic Aperture Imaging in Medical Ultrasound : The Dual Stage Beamformer Approach

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2010

Standard

Implementation of Synthetic Aperture Imaging in Medical Ultrasound : The Dual Stage Beamformer Approach. / Jensen, Jørgen Arendt; Kortbek, Jacob; Nikolov, Svetoslav; Hemmsen, Martin Christian; Tomov, Borislav Gueorguiev.

European Conference on Synthetic Aperture Radar. IEEE, 2010.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2010

Harvard

APA

CBE

MLA

Vancouver

Author

Jensen, Jørgen Arendt; Kortbek, Jacob; Nikolov, Svetoslav; Hemmsen, Martin Christian; Tomov, Borislav Gueorguiev / Implementation of Synthetic Aperture Imaging in Medical Ultrasound : The Dual Stage Beamformer Approach.

European Conference on Synthetic Aperture Radar. IEEE, 2010.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2010

Bibtex

@inbook{fceff9de8c534c7f9c14133888680743,
title = "Implementation of Synthetic Aperture Imaging in Medical Ultrasound",
publisher = "IEEE",
author = "Jensen, {Jørgen Arendt} and Jacob Kortbek and Svetoslav Nikolov and Hemmsen, {Martin Christian} and Tomov, {Borislav Gueorguiev}",
year = "2010",
isbn = "978-3-8007-3272-2",
booktitle = "European Conference on Synthetic Aperture Radar",

}

RIS

TY - GEN

T1 - Implementation of Synthetic Aperture Imaging in Medical Ultrasound

T2 - European Conference on Synthetic Aperture Radar

A1 - Jensen,Jørgen Arendt

A1 - Kortbek,Jacob

A1 - Nikolov,Svetoslav

A1 - Hemmsen,Martin Christian

A1 - Tomov,Borislav Gueorguiev

AU - Jensen,Jørgen Arendt

AU - Kortbek,Jacob

AU - Nikolov,Svetoslav

AU - Hemmsen,Martin Christian

AU - Tomov,Borislav Gueorguiev

PB - IEEE

PY - 2010

Y1 - 2010

N2 - The main advantage of medical ultrasound imaging is its real time capability, which makes it possible to visualize dynamic structures in the human body. Real time synthetic aperture imaging puts very high demands on the hardware, which currently cannot be met. A method for reducing the number of calculations and still retain the many advantages of SA imaging is described. It consists of a dual stage beamformer, where the first can be a simple fixed focus analog beamformer and the second an ordinary digital ultrasound beamformer. The performance and constrictions of the approach is described.

AB - The main advantage of medical ultrasound imaging is its real time capability, which makes it possible to visualize dynamic structures in the human body. Real time synthetic aperture imaging puts very high demands on the hardware, which currently cannot be met. A method for reducing the number of calculations and still retain the many advantages of SA imaging is described. It consists of a dual stage beamformer, where the first can be a simple fixed focus analog beamformer and the second an ordinary digital ultrasound beamformer. The performance and constrictions of the approach is described.

KW - Synthetic Aperture

KW - Ultrasound

SN - 978-3-8007-3272-2

BT - European Conference on Synthetic Aperture Radar

ER -