Small on-site greywater treatment and reuse plants are susceptible to high short-term variation in flow and pollutant concentrations. As demonstrated in this study of a bathroom greywater plant in Copenhagen, Denmark, the flow ranges from no-flow periods to high-flow periods reaching 34 l min−1. Concentrations of both macro- and micro-pollutants (organic matter and parabens) were found to range by several orders of magnitude in the influent, based on sampling every 20 min. Paraben degradation was proven to occur in the rotating biological contactor (RBC), while the remnant organic matter in the effluent was proved not to be readily degradable. Ammonium content, presumably from urine contamination, was found to undergo nitrification in the RBC. Mass flow (daily loads) for individual substances was calculated for several pollutants. Macropollutants were found to be generated in low numbers of grams per person per day, whereas the paraben loadings were below 1 mg per person per day. These data are highly relevant for comparing decentralised treatment options with existing end-of-pipe treatments, for feeding into risk assessments and for design purposes.
Original languageEnglish
JournalEcological Engineering
Publication date2009
Volume35
Journal number5
Pages661-669
ISSN0925-8574
DOIs
StatePublished
CitationsWeb of Science® Times Cited: 20

Keywords

  • On-site treatment, Parabens, RBC, Grey wastewater, Mass flow, Daily load
Download as:
Download as PDF
Select render style:
APAAuthorCBEHarvardMLAStandardVancouverShortLong
PDF
Download as HTML
Select render style:
APAAuthorCBEHarvardMLAStandardVancouverShortLong
HTML
Download as Word
Select render style:
APAAuthorCBEHarvardMLAStandardVancouverShortLong
Word

ID: 5886389