Analysis of single blow effectiveness in non-uniform parallel plate regenerators

Publication: Research - peer-reviewJournal article – Annual report year: 2011

View graph of relations

Non-uniform distributions of plate spacings in parallel plate regenerators have been found to induce loss of performance. In this paper, it has been investigated how variations of three geometric parameters (the aspect ratio, the porosity, and the standard deviation of the plate spacing) affects this loss in a single blow model of a parallel-plate regenerator. Simple analytical functions for the magnitude and the time scale of the reduction of performance are presented and compared to numerical results.
Original languageEnglish
JournalInternational Journal of Heat and Mass Transfer
Publication date2011
Volume54
Issue21-22
Pages4746-4751
ISSN0017-9310
DOIs
StatePublished
CitationsWeb of Science® Times Cited: 4

Keywords

  • Non-uniform, Distribution, Performance, Modeling, Regenerator