This paper proposes an improved partially interleaved structure for high-voltage (Several kV) high-frequency (Several hundred kHz) multiple output applications. Six structures are compared with the leakage inductance, AC capacitance and the rate of AC/DC resistance taken into consideration. The proposed structure features lower leakage inductance, smaller AC capacitance and lower rate of AC-DC resistance, which is suitable for high-frequency high-efficiency applications. A planar transformer with the proposed structure was built and tested in an LCLC resonant converter, where the input voltage is 40V, output is 4800V, switching frequency 500 kHz and the efficiency is 96.8%, which validates the analysis.
Original languageEnglish
JournalI E E E Transactions on Industrial Electronics
Volume66
Issue number4
Pages (from-to)2691-2702
Number of pages12
ISSN0278-0046
DOIs
Publication statusPublished - 2018
CitationsWeb of Science® Times Cited: No match on DOI

    Research areas

  • Planar transformer, Improved partially interleaved structure, High-voltage, High-frequency, Multiple-output
Download as:
Download as PDF
Select render style:
APAAuthorCBE/CSEHarvardMLAStandardVancouverShortLong
PDF
Download as HTML
Select render style:
APAAuthorCBE/CSEHarvardMLAStandardVancouverShortLong
HTML
Download as Word
Select render style:
APAAuthorCBE/CSEHarvardMLAStandardVancouverShortLong
Word

Download statistics

No data available

ID: 152865770