Active Match Load Circuit Intended for Testing Piezoelectric Transformers

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2012

Standard

Active Match Load Circuit Intended for Testing Piezoelectric Transformers. / Andersen, Thomas; Rødgaard, Martin Schøler; Andersen, Michael A. E.

6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology, 2012.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2012

Harvard

Andersen, T, Rødgaard, MS & Andersen, MAE 2012, 'Active Match Load Circuit Intended for Testing Piezoelectric Transformers'. in 6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology., 10.1049/cp.2012.0169

APA

Andersen, T., Rødgaard, M. S., & Andersen, M. A. E. (2012). Active Match Load Circuit Intended for Testing Piezoelectric Transformers. In 6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology. 10.1049/cp.2012.0169

CBE

Andersen T, Rødgaard MS, Andersen MAE. 2012. Active Match Load Circuit Intended for Testing Piezoelectric Transformers. In 6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology. Available from: 10.1049/cp.2012.0169

MLA

Andersen, Thomas, Martin Schøler Rødgaard, and Michael A. E. Andersen "Active Match Load Circuit Intended for Testing Piezoelectric Transformers". 6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology. 2012. Available: 10.1049/cp.2012.0169

Vancouver

Andersen T, Rødgaard MS, Andersen MAE. Active Match Load Circuit Intended for Testing Piezoelectric Transformers. In 6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology. 2012. Available from: 10.1049/cp.2012.0169

Author

Andersen, Thomas; Rødgaard, Martin Schøler; Andersen, Michael A. E. / Active Match Load Circuit Intended for Testing Piezoelectric Transformers.

6th IET International Conference on Power Electronics, Machines and Drives. Institution of Engineering and Technology, 2012.

Publication: Research - peer-reviewArticle in proceedings – Annual report year: 2012

Bibtex

@inbook{0b29bf9075c44d2aa22a214f4ab4260d,
title = "Active Match Load Circuit Intended for Testing Piezoelectric Transformers",
keywords = "Match load, Piezoelectric transformer.",
publisher = "Institution of Engineering and Technology",
author = "Thomas Andersen and Rødgaard, {Martin Schøler} and Andersen, {Michael A. E.}",
year = "2012",
doi = "10.1049/cp.2012.0169",
isbn = "9781849196161",
booktitle = "6th IET International Conference on Power Electronics, Machines and Drives",

}

RIS

TY - GEN

T1 - Active Match Load Circuit Intended for Testing Piezoelectric Transformers

A1 - Andersen,Thomas

A1 - Rødgaard,Martin Schøler

A1 - Andersen,Michael A. E.

AU - Andersen,Thomas

AU - Rødgaard,Martin Schøler

AU - Andersen,Michael A. E.

PB - Institution of Engineering and Technology

PY - 2012

Y1 - 2012

N2 - An adjustable high voltage active load circuit for voltage amplitudes above 100 volts, especially intended for resistive matching the output impedance of a piezoelectric transformer (PT) is proposed in this paper. PTs have been around for over 50 years, were C. A. Rosen is common known for his famous Rosen type design back in the 1950s. After the discovered of new piezoelectric materials and new PT designs have been invented, the PT based power converters are in the area where they can outperform tradition electromagnetic based converters in certain applications. The performance of PTs can be measured and compared on its zero voltage switching (ZVS) factor, power density, and efficiency. Common for these three parameters are that they need to be measured with a match load connected at the output of the PT.

AB - An adjustable high voltage active load circuit for voltage amplitudes above 100 volts, especially intended for resistive matching the output impedance of a piezoelectric transformer (PT) is proposed in this paper. PTs have been around for over 50 years, were C. A. Rosen is common known for his famous Rosen type design back in the 1950s. After the discovered of new piezoelectric materials and new PT designs have been invented, the PT based power converters are in the area where they can outperform tradition electromagnetic based converters in certain applications. The performance of PTs can be measured and compared on its zero voltage switching (ZVS) factor, power density, and efficiency. Common for these three parameters are that they need to be measured with a match load connected at the output of the PT.

KW - Match load

KW - Piezoelectric transformer.

U2 - 10.1049/cp.2012.0169

DO - 10.1049/cp.2012.0169

SN - 9781849196161

BT - 6th IET International Conference on Power Electronics, Machines and Drives

T2 - 6th IET International Conference on Power Electronics, Machines and Drives

ER -