A portable luminescence dating instrument

Publication: Research - peer-reviewJournal article – Annual report year: 2011

Standard

A portable luminescence dating instrument. / Kook, M.H.; Murray, A.S.; Lapp, Torben; Denby, P.H.; Ankjærgaard, Christina; Thomsen, Kristina Jørkov; Jain, Mayank; Choi, J.H.; Kim, G.H.

In: Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms, Vol. 269, No. 12, 2011, p. 1370-1378.

Publication: Research - peer-reviewJournal article – Annual report year: 2011

Harvard

APA

CBE

MLA

Vancouver

Author

Kook, M.H.; Murray, A.S.; Lapp, Torben; Denby, P.H.; Ankjærgaard, Christina; Thomsen, Kristina Jørkov; Jain, Mayank; Choi, J.H.; Kim, G.H. / A portable luminescence dating instrument.

In: Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms, Vol. 269, No. 12, 2011, p. 1370-1378.

Publication: Research - peer-reviewJournal article – Annual report year: 2011

Bibtex

@article{72c3ef7431c14a938593a6c5ff3b8a92,
title = "A portable luminescence dating instrument",
keywords = "Radiation physics, Strålingsfysik",
publisher = "Elsevier BV",
author = "M.H. Kook and A.S. Murray and Torben Lapp and P.H. Denby and Christina Ankjærgaard and Thomsen, {Kristina Jørkov} and Mayank Jain and J.H. Choi and G.H. Kim",
year = "2011",
doi = "10.1016/j.nimb.2011.03.014",
volume = "269",
number = "12",
pages = "1370--1378",
journal = "Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",

}

RIS

TY - JOUR

T1 - A portable luminescence dating instrument

A1 - Kook,M.H.

A1 - Murray,A.S.

A1 - Lapp,Torben

A1 - Denby,P.H.

A1 - Ankjærgaard,Christina

A1 - Thomsen,Kristina Jørkov

A1 - Jain,Mayank

A1 - Choi,J.H.

A1 - Kim,G.H.

AU - Kook,M.H.

AU - Murray,A.S.

AU - Lapp,Torben

AU - Denby,P.H.

AU - Ankjærgaard,Christina

AU - Thomsen,Kristina Jørkov

AU - Jain,Mayank

AU - Choi,J.H.

AU - Kim,G.H.

PB - Elsevier BV

PY - 2011

Y1 - 2011

N2 - We describe a portable luminescence reader suitable for use in remote localities in the field. The instrument weighs about 8kg and is based around a 30mm bialkali photomultiplier detecting signals through a glass filter centered on 340nm. Stimulation is by 470nm blue LEDs (24W in total) operating in both continuous wave and pulsed mode; photon counting can be gated such that it is active only during the pulse off-period. There are also two bleaching light sources (470nm, 5W and 940nm, 3W), and the luminescence signals can be regenerated using a cold-cathode 30kV X-ray tube, delivering ∼0.06Gy.s−1. The three position sampling device has a heating element under each sampling position, able to heat the sample at 3°C.s−1 up to at least 250°C. The sampler can be inserted into unconsolidated sediments, and is designed to prevent exposure of the mineral grains to ambient light during sampling. The performance of the instrument in terms of sensitivity and reproducibility is comparable to that of the standard bench-top laboratory TL/OSL Risø reader.We show that the portable luminescence reader is able to measure accurately an ∼20Gy quartz burial dose in a natural (unpretreated, no mineral separation) sandy sediment. We also show that, because of the configuration of the measurement head, the portable reader can be used to measure radioluminescence at elevated temperature in the presence of stimulation light; this facility is not available on conventional bench-top instruments. It is concluded that the portable luminescence reader can be used to accurately determine the quartz burial dose in loose sandy sediments in the field, without sample preparation or darkroom facilities.

AB - We describe a portable luminescence reader suitable for use in remote localities in the field. The instrument weighs about 8kg and is based around a 30mm bialkali photomultiplier detecting signals through a glass filter centered on 340nm. Stimulation is by 470nm blue LEDs (24W in total) operating in both continuous wave and pulsed mode; photon counting can be gated such that it is active only during the pulse off-period. There are also two bleaching light sources (470nm, 5W and 940nm, 3W), and the luminescence signals can be regenerated using a cold-cathode 30kV X-ray tube, delivering ∼0.06Gy.s−1. The three position sampling device has a heating element under each sampling position, able to heat the sample at 3°C.s−1 up to at least 250°C. The sampler can be inserted into unconsolidated sediments, and is designed to prevent exposure of the mineral grains to ambient light during sampling. The performance of the instrument in terms of sensitivity and reproducibility is comparable to that of the standard bench-top laboratory TL/OSL Risø reader.We show that the portable luminescence reader is able to measure accurately an ∼20Gy quartz burial dose in a natural (unpretreated, no mineral separation) sandy sediment. We also show that, because of the configuration of the measurement head, the portable reader can be used to measure radioluminescence at elevated temperature in the presence of stimulation light; this facility is not available on conventional bench-top instruments. It is concluded that the portable luminescence reader can be used to accurately determine the quartz burial dose in loose sandy sediments in the field, without sample preparation or darkroom facilities.

KW - Radiation physics

KW - Strålingsfysik

U2 - 10.1016/j.nimb.2011.03.014

DO - 10.1016/j.nimb.2011.03.014

JO - Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments & Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

IS - 12

VL - 269

SP - 1370

EP - 1378

ER -