External Organisations

  • Chalmers Tekniska Högskola, Sweden
  • SP Sveriges Provnings- och Forskningsinstitut, Sweden

View graph of relations

NOrdtest project

To evaluate the reproducibility of the wedge-splitting test method and to provide guidelines, a round robin study was conducted in which three labs participated. The participating labs were: § DTU – the Technical University of Denmark, Department of Civil Engineering; § CTH – Chalmers University of Technology, Department of Structural Engineering and Mechanics; and § SP – the Swedish National Testing and Research Institute. Two different mixes were investigated; the difference between the mixes was the fibre length (Mix 1 with 40 kg of 35 mm long fibres and Mix 2 with 40 kg of 60 mm long fibres). The test results from each lab were analysed and a study of the variation was performed. From the study of the intra-lab variations, it is evident that the variations of the steel fibre-reinforced concrete properties are significant. The coefficient of variance for the splitting load was found to vary between 20 to 40%. The investigation of the inter-lab variation, based on an analysis of variance (ANOVA) indicated that there is no inter-lab variation. The test result can be said to be independent of the testing location and the equipment used (with or without CMOD-control). The conclusions that can be drawn from this study are that: § the wedge-splitting test method is a suitable test method for assessment of fracture properties of steel fibre-reinforced concrete; § the test method is easy to handle and relatively fast to execute § the test can be run with CMOD-control or without, in a machine with a constant cross-head displacement rate (if rate is equal to or less than 0.25 mm/min); § due to variations in fibre distribution, the scatter of the test results is high; § the dimensions of the specimen (height, width, and thickness) should, if possible, be four times the maximum fibre length, or at least more than three times the fibre length; § using inverse analysis, the tensile fracture properties can be interpreted from the test result as a bi-linear stress-crack opening relationship. Key words: Fibre-reinforced concrete, fracture testing, wedge-splitting test method, round-robin test, Nordtest.
StatusCompleted
Period01/01/0431/12/04
Financing sourceForsk. Andre offentlige og private - Nordiske
Research programmeForsk. Andre offentlige og private - Nordiske
Amount333,000.00 Danish kroner
Project ID25580
Download as:
Download as PDF
Select render style:
ShortLong
PDF
Download as HTML
Select render style:
ShortLong
HTML
Download as Word
Select render style:
ShortLong
Word

ID: 2259612